Tuesday, 17 March 2020

AX 2012 Add reference not showing options on number sequence

Issue : Add reference not showing options on number sequence.

Above issue may arise if a customized number sequence is created through code.

Solution:
  1. Go to AOT>Tables> NumberSequenceTable
  2. Open table and find for number sequence created and note recid.
  1. Open NumberSequenceScope table and find dataArea for which number sequence created. Note recId.
  2. Open NumberSequenceDataType table and find datatype created (number sequence required for ex. Service order id). Note recid.
  1. Open NumberSequenceReference table and filter datatypeid field with recid of NumberSequenceDataType table .
  2. It will show missing number sequence id. Set number sequence table recid in numberSequenceId field.
  1. Update NumberSequenceScope field on NumberSequenceTable .




Monday, 4 November 2019

AX 2012 Invalid data container type

Error: Invalid data container type 
While creating service from AIF document service wizard error below


cid:image001.jpg@01D5857F.FB9C6850


Solution:

  1. Compile forward AfStronglyTypedDataContainer class ( this will take approx.. 15 to 20 minutes)
  2. Full CIL